Leave Your Message
5000L Stainless Steel Water Tank - China Suppliers & Factory for Commercial Thermal Energy Solutions
Hot Products

5000L Stainless Steel Water Tank - China Suppliers & Factory for Commercial Thermal Energy Solutions

Ultra-Large Capacity Duplex 2205 Thermal Energy Commercial Tank | 75mm PU Insulation | Infrastructure-Grade Design

Introducing our 5000L ultra-large stainless steel thermal storage tank, specially designed for district energy networks, renewable power systems, and industrial-scale heating infrastructure. With its Duplex 2205 construction and 75mm insulation, this tank is engineered for long-cycle thermal stability and peak load balancing, making it an ideal solution for energy management in China.

As a leading supplier of thermal storage solutions, our SST 5000L stainless steel tank is the largest capacity model available for commercial and industrial heating systems. This tank serves as a central thermal energy reservoir, allowing for large-scale heat storage and redistribution, thereby stabilizing complex energy networks.

Constructed from high-quality Duplex 2205, SUS316L, or SUS304 stainless steel, our tank offers exceptional mechanical strength, corrosion resistance, and long-term durability, even under continuous high-load operation. Its reinforced structural design enables seamless integration into multi-source energy ecosystems, including renewable generation, district heating plants, industrial waste heat recovery systems, and centralized energy hubs. Trust our factory in China to provide you with the most reliable and efficient thermal energy storage solutions.

    Technical Specifications

    Product Range

    Commercial tank

    Volume Range

    5000L

    Inner Diameter

    Φ1900mm

    Outer Diameter

    Φ2050mm

    Insulation Thickness

    75mm

    Height

    2500mm

    Cylinder Material

    SUS304 / SUS316L / DUPLEX

    Outer Shell

    Color board or Stainless steel SUS304

    Electric Heater

    1.5kW & 3kW 220~240V 50Hz 1Phase

    Exchange Coil Material

    SUS316L

    Exchange Coil Diameter

    32mm, 35mm

    Connections

    1”, 5/4”, 6/4”, 2”

    Working Pressure

    0.6 MPa

    Maximum Pressure

    1.0 Mpa

    Application

    Apartment Buildings & Residential Complexes

    Apartment Buildings & Residential Complexes

    Large apartment buildings and residential complexes require a stable centralized hot water supply for hundreds of residents during peak usage periods. A 5000L stainless steel water tank provides high-capacity thermal storage, ensuring consistent water temperature and pressure across multiple buildings. Combined with heat pumps or gas boilers, it improves system efficiency while reducing operating costs for large residential developments.

    Hotel & Resort Hot Water Systems

    Hotel & Resort Hot Water Systems

    Large hotels, resorts, and hospitality facilities require continuous hot water for guest rooms, restaurants, spas, laundry, and kitchens. The 5000L commercial water tank stores large volumes of heated water to handle simultaneous peak demand while reducing boiler or heat pump cycling. Its Duplex 2205 construction provides outstanding durability for long-term commercial operation.

    Hospital & Healthcare Facilities

    Hospital & Healthcare Facilities

    Hospitals and healthcare facilities depend on uninterrupted hot water for patient care, sterilization, kitchens, laundry, and sanitation. A 5000L thermal storage tank provides reliable hot water reserves throughout the day, ensuring stable operation even during peak consumption. Optional SUS316L construction offers enhanced corrosion resistance and hygienic performance for demanding healthcare environments.

    Farm & Agricultural Operations

    Farm & Agricultural Operations

    Large dairy farms, livestock operations, and agricultural facilities require substantial hot water for equipment cleaning, livestock sanitation, and greenhouse heating. A 5000L insulated stainless steel tank provides reliable thermal storage for daily farm operations while reducing energy consumption. Duplex 2205 material offers superior corrosion resistance in harsh agricultural environments.

    Commercial Heat Pump Systems

    Commercial Heat Pump Systems

    The 5000L tank is ideal for commercial air source heat pump and hybrid heating systems, acting as a high-capacity thermal storage buffer for offices, hotels, apartment buildings, and public facilities. It minimizes compressor cycling, improves heat pump efficiency, and ensures a continuous hot water supply during periods of high demand.

    Frequently Asked Questions

    Q What materials are available for the inner cylinder of the 5000L tank?

    The cylinder is manufactured from high-grade SUS304, SUS316L, or Duplex (such as Duplex 2205) stainless steel, offering outstanding anti-corrosion protection and high structural longevity for commercial use.

    Q What are the pressure capabilities of this commercial storage tank?

    The 5000L tank operates at a standard rated working pressure of 0.6 MPa and can handle a maximum test pressure of up to 1.0 MPa.

    Q How does the 75mm insulation layer help reduce energy costs?

    The high-density 75mm thermal insulation layer drastically limits standby heat loss, keeping stored water hot for extended periods and preventing heat pump or boiler short-cycling.

    Q What are the specifications of the built-in exchange coils and electric backup?

    The internal heat exchange coils are made of corrosion-resistant SUS316L with diameters of 32mm or 35mm. Additionally, backup electric heating elements of 1.5kW & 3kW (220~240V 50Hz 1Phase) are available.

    Q What pipe connection sizes are supported on the tank?

    The 5000L commercial tank is designed with versatile multi-port connection sizes including 1”, 5/4”, 6/4”, and 2” to fit standard commercial plumbing and circulation systems.

    Q How does this tank function within a commercial heat pump setup?

    It acts as a high-capacity thermal storage buffer that stores large volumes of heated water during off-peak times, stabilizing temperature delivery during peak demand while protecting compressors from frequent cycling.